| Number |
Title |
| TN93 |
Building information modelling - Principles for building envelopes (10pp) |
| TN92 |
Simplified method for assessing glazing in Class 2 roofs (3 pp) |
| TN91 |
Structural performance of systemised walls - bracket calculations (in preparation) |
| TN90 |
Structural performance of systemised walls - Bracket requirements and principles (10 pp) - supersedes TN28 |
| TN89 |
Structural performance of systemised walls - Open profiles (in preparation) |
| TN88 |
Structural performance of systemised walls - Buckling and torsion (in preparation) |
| TN87 |
Structural performance of systemised walls - Closed profiles (in preparation) |
| TN86 |
Structural performance of systemised walls - Connections (10) |
| TN85 |
Structural performance of systemised walls - Design charts and profile data (9 pp) |
| TN84 |
Structural performance of systemised walls - Introduction (9 pp) |
| TN83 |
Interfaces and joints - breathable seals (in preparation) |
| TN82 |
Interfaces and joints - sealant movement joints (in preparation) |
| TN81 |
Interfaces and joints - sealant materials (in preparation) |
| TN80 |
Interfaces and joints - thermal performance (in preparation) |
| TN79 |
Interfaces and joints - air permeability and water penetration resistance (in preparation) |
| TN78 |
Interfaces and joints - introduction (7pp) |
| TN77 |
Assessment and certification of rainscreen systems (4 pp) |
| TN76 |
Impact performance of building envelopes: method for impact testing cladding panels (6 pp) - supersedes TN52 |
| TN75 |
Impact performance of building envelopes: guidance on specification (10 pp) - supersedes TN52 |
| TN74 |
Ventilation (14 pp) - supersedes TN32 |
| TN73 |
Fire performance of curtain walls and rainscreens (7 pp) |
| TN72 |
External shading devices (14 pp) |
| TN71 |
Standards and performance classification of windows and doors (11 pp) |
| TN70 |
Thermal and moisture performance of cavities in building envelopes (6 pp) |
| TN69 |
Selection of glass to prevent falls from height (8 pp) |
| TN68 |
Overhead glazing (8 pp) |
| TN67 |
Safety and fragility of overhead glazing: testing and assessment (5 pp) - supersedes TN42 |
| TN66 |
Safety and fragility of overhead glazing: guidance on specification (11 pp) - supersedes TN42 |
| TN65 |
Thermal fracture of glass (6pp) |
| TN64 |
Gaskets (12 pp) |
| TN63 |
Glass breakage (10 pp) |
| TN62 |
Specification of insulating glass units (10 pp) |
| TN61 |
Glass types (9 pp) |
| TN60 |
Performance of externally rendered cladding systems (6 pp) |
| TN59 |
Introduction to externally rendered cladding systems (6 pp) |
| TN58 |
Repairs to glass (3 pp) |
| TN57 |
Cladding movement (7 pp) |
| TN56 |
Accommodation of structural movement (12 pp) |
| TN55 |
Movement accommodation in building envelopes (6 pp) |
| TN54 |
Self-cleaning glass (8 pp) |
| TN53 |
Method statements for the construction of building envelopes (11pp) |
| TN52 |
Impact performance of cladding (10 pp) - replaced by TN75 and TN76 |
| TN51 |
Environmental control glasses (12 pp) |
| TN50 |
Solar gain and shading (16 pp) |
| TN49 |
U-value of curtain walls (5 pp) |
| TN48 |
U-values of windows (7 pp) |
| TN47 |
Overall building envelope U-values (9 pp) |
| TN46 |
Introduction to building energy transfer (10 pp) |
| TN45 |
Thermography and facades (9 pp) |
| TN44 |
Whole building air leakage tests (7 pp) |
| TN43 |
Film backed glass (6 pp) |
| TN42 |
Safety and fragility of glazed roofing - replaced by TN66/TN67 |
| TN41 |
Site testing for watertightness (6 pp) |
| TN40 |
Sound environment behind a building envelope (5 pp) |
| TN39 |
Sound transmission through building envelopes (5 pp) |
| TN38 |
Acoustic performance of windows (7 pp) |
| TN37 |
Introduction to building envelope acoustics (8 pp) |
| TN36 |
Assessing the appearance of metals and finishes (6 pp) |
| TN35 |
Assessing the appearance of glass (14 pp) |
| TN34 |
Assessing the appearance of new curtain walling (4 pp) |
| TN33 |
Breather membranes and vapour control layers in walls (6 pp) |
| TN32 |
Ventilation (6 pp) - replaced by TN74 |
| TN31 |
Pressure effects on insulated glazing units (6 pp) |
| TN30 |
Cladding of buildings subject to earthquakes (5 pp) |
| TN29 |
Design of curtain wall brackets (7 pp) |
| TN28 |
Performance requirements for curtain wall brackets - replaced by TN90 |
| TN27 |
Structural design of stick curtain walling - sample calculations (8 pp) |
| TN26 |
Introduction to structural design of stick curtain walling (6 pp) |
| TN25 |
Selection of applied finishes for metal (7 pp) |
| TN24 |
Corrosion (7 pp) |
| TN23 |
Cladding metals 2 - non-ferrous metals (7 pp) |
| TN22 |
Cladding metals 1- ferrous metals (7 pp) |
| TN21 |
Tolerance, fit and appearance of cladding (8 pp) |
| TN20 |
Design of sealant joints (6 pp) |
| TN19 |
Selection and use of sealants ( (7 pp) |
| TN18 |
Gaskets - replaced by TN64 |
| TN17 |
Weathertightness and drainage (7 pp) |
| TN16 |
Joints in the building envelope (7 pp) |
| TN15 |
Cladding types (7 pp) |
| TN14 |
Curtain wall types (7 pp) |
| TN13 |
Glass breakage (6 pp) - partially replaced by TN63 |
| TN12 |
Specification of hermetically sealed glass units (7 pp) - replaced by TN62 |
| TN11 |
Glass types (7 pp) - replaced by TN61 |
| TN10 |
Superseded - replaced by TN41 |
| TN09 |
Testing pressures (4 pp) |
| TN08 |
Selection of windows - a checklist for specifiers (8 pp) |
| TN07 |
Threat resistant fenestration (9 pp) |
| TN06 |
Pressure-equalisation (9 pp) |
| TN04 |
Issues relating to wind loading on tall buildings (10 pp) |
| TN05 |
Wind tunnel testing (4 pp) |
| TN03 |
Wind loading on wall cladding and windows of low rise buildings (12 pp) |
| TN02 |
Introduction to wind loading on cladding (8 pp) |
| TN01 |
Representing air leakage through windows and glazed cladding systems (8 pp) |